<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>elatric wire for home &#8211; JYTOP Cable</title>
	<atom:link href="https://portuguese.baoliyy.com/tag/elatric-wire-for-home/feed/" rel="self" type="application/rss+xml" />
	<link>https://portuguese.baoliyy.com</link>
	<description>Fabricação CONDUTOR AAC / AAAC / ACSR, cabo XLPE, cabo PVC, cabo ABC, cabo de alimentação</description>
	<lastBuildDate>Tue, 10 Sep 2019 14:13:13 +0000</lastBuildDate>
	<language>pt-PT</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.29</generator>
	<item>
		<title>PVC insulated wire electric cable wire 1.5mm2 wire for home application</title>
		<link>https://portuguese.baoliyy.com/pvc-insulated-wire-electric-cable-wire-1-5mm2-wire-for-home-application/</link>
				<comments>https://portuguese.baoliyy.com/pvc-insulated-wire-electric-cable-wire-1-5mm2-wire-for-home-application/#respond</comments>
				<pubDate>Tue, 10 Sep 2019 14:13:13 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[jinshui]]></category>
		<category><![CDATA[elatric wire for home]]></category>
		<category><![CDATA[electric cable]]></category>
		<category><![CDATA[electrical cable wire 1.5mm2]]></category>

		<guid isPermaLink="false">https://portuguese.baoliyy.com/pvc-insulated-wire-electric-cable-wire-1-5mm2-wire-for-home-application/</guid>
				<description><![CDATA[PVC isolou o fio el&#233;trico cabo de fio 1.5mm2 fio para aplica&#231;&#227;o em casa &#160; Caracter&#237;sticas de fios el&#233;tricos A longo prazo da temperatura de trabalho do fio el&#233;trico deve ser inferior a grau 70.E a longo prazo da temperatura de trabalho do RV-90 90 el&#233;trica do fio deve ser inferior a grau. &#160; Aplica&#231;&#227;o [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p style="font-size: 18.0px">PVC isolou o fio el&eacute;trico cabo de fio 1.5mm2 fio para aplica&ccedil;&atilde;o em casa</p>
<p style="font-size: 18.0px"><strong>&nbsp;</strong></p>
<p style="font-size: 18.0px"><span style="font-weight: bold;font-size: 16.0px;font-style: inherit;line-height: 24.0px;font-family: arial , helvetica">Caracter&iacute;sticas de fios el&eacute;tricos</span></p>
<div style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial , helvetica;line-height: 15.0px;vertical-align: baseline"><span style="background-color: #ccffcc"><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;vertical-align: baseline"><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 14.0px;font-style: inherit;line-height: 21.0px;vertical-align: baseline">A longo prazo da temperatura de trabalho do fio el&eacute;trico deve ser inferior a grau 70.</span></span><span style="font-size: 14.0px;font-style: inherit;line-height: 21.0px">E a longo prazo da temperatura de trabalho do RV-90 90 el&eacute;trica do fio deve ser inferior a grau.</span></span></div>
<div style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial , helvetica;line-height: 15.0px;vertical-align: baseline">&nbsp;</div>
<div style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial , helvetica;line-height: 15.0px;vertical-align: baseline">
<div style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial , helvetica;line-height: 15.0px;vertical-align: baseline">
<p style="border: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;vertical-align: baseline"><strong><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;vertical-align: baseline;color: #000000"><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 16.0px;font-style: inherit;line-height: 24.0px;vertical-align: baseline">Aplica&ccedil;&atilde;o</span></span></strong></p>
</div>
<div style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial , helvetica;line-height: 15.0px;vertical-align: baseline"><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-size: 14.0px;font-style: inherit;line-height: inherit;vertical-align: baseline;color: #000000;background-color: #ccffcc"><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-style: inherit;line-height: 21.0px;vertical-align: baseline">Fios el&eacute;tricos s&atilde;o amplamente utilizados como conectores de condu&ccedil;&atilde;o, ilumina&ccedil;&atilde;o, equipamentos el&eacute;tricos, instrumentos e equipamentos de telecomunica&ccedil;&otilde;es com tens&atilde;o avaliado at&eacute; 450/750 v.</span><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-style: inherit;line-height: 21.0px;vertical-align: baseline"><span style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-style: inherit;line-height: 27.0px;vertical-align: baseline">Usado para eletrodom&eacute;sticos, energia e ilumina&ccedil;&atilde;o e os lugares onde flex&iacute;vel exige. Arquitetura e fios de pano de casa.</span></span></span></div>
<div style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial , helvetica;line-height: 15.0px;vertical-align: baseline">&nbsp;</div>
<div style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial , helvetica;line-height: 15.0px;vertical-align: baseline">&nbsp;</div>
<div style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial , helvetica;line-height: 15.0px;vertical-align: baseline">&nbsp;</div>
<div style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial , helvetica;line-height: 15.0px;vertical-align: baseline"><span style="font-weight: bold;font-size: 16.0px;font-style: inherit;line-height: 24.0px">Tipo e Nome</span></div>
<div style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial , helvetica;line-height: 15.0px;vertical-align: baseline">
<div style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial , helvetica;line-height: 15.0px;vertical-align: baseline">
<div style="overflow:auto"><table style="margin: 0.0px;padding: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;width: 929.0px" border="1" cellspacing="0" cellpadding="1">
<tbody>
<tr style="margin: 0.0px;padding: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit">
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="font-size: 16.0px;background-color: #ccffcc">Tipo</span></td>
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="font-size: 16.0px;background-color: #ccffcc">Nome</span></td>
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="font-size: 16.0px;background-color: #ccffcc">Colocando o lugar e exig&ecirc;ncia</span></td>
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="background-color: #99ccff">Longo prazo temperatura de trabalho</span></td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit">
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none" rowspan="2"><span style="font-size: 16.0px;background-color: #ccffcc">227IEC01/05</span><br /><span style="font-size: 16.0px;background-color: #ccffcc">BV</span><br /><span style="font-size: 16.0px;background-color: #ccffcc">BLV</span></td>
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="font-size: 16.0px;background-color: #ccffcc">Fios de cobre DO condutor isolado PVC</span></td>
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none" rowspan="2"><span style="font-size: 16.0px;background-color: #ccffcc">Fixo colocado dentro, condutas etc.</span></td>
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none" rowspan="2"><span style="background-color: #99ccff">70</span></td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit">
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="font-size: 16.0px;background-color: #ccffcc">Condutor de alum&iacute;nio PVC isolado fios</span></td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit">
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="font-size: 16.0px;background-color: #ccffcc">227IEC07</span><br /><span style="font-size: 16.0px;background-color: #ccffcc">BV-90</span></td>
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="font-size: 16.0px;background-color: #ccffcc">Resistente ao calor de cobre DO condutor PVC isolado fios em 90</span></td>
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="font-size: 16.0px;background-color: #ccffcc">Principalmente ser colocados nos locais de ambiente de alta temperatura e pode ser colocado dentro, condutas.</span></td>
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="background-color: #99ccff">90</span></td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit">
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="font-size: 16.0px;background-color: #ccffcc">BVR</span></td>
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="font-size: 16.0px;background-color: #ccffcc">Condutor de cobre PVC isolou o fio flex&iacute;vel</span></td>
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="font-size: 16.0px;background-color: #ccffcc">Ser para a coloca&ccedil;&atilde;o permanente lugar onde flex&iacute;vel</span></td>
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="background-color: #99ccff">70</span></td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit">
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="font-size: 16.0px;background-color: #ccffcc">227IEC10</span><br /><span style="font-size: 16.0px;background-color: #ccffcc">BV</span></td>
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="font-size: 16.0px;background-color: #ccffcc">Fios de cobre DO condutor PVC isolado PVC revestido rodada</span></td>
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none" rowspan="4"><span style="font-size: 16.0px;background-color: #ccffcc">Fixo previsto, ajuste para os locais com prote&ccedil;&atilde;o mec&acirc;nica elevada e umidade local. pode ser colocado no ar ou no subsolo.</span></td>
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none" rowspan="4"><span style="background-color: #99ccff">70</span></td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit">
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="font-size: 16.0px;background-color: #ccffcc">BLV</span></td>
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="font-size: 16.0px;background-color: #ccffcc">Alum&iacute;nio condutor PVC isolado PVC revestido fios redondos</span></td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit">
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="font-size: 16.0px;background-color: #ccffcc">BVB</span></td>
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="font-size: 16.0px;background-color: #ccffcc">Condutor de cobre PVC isolado PVC revestido fios apartamento</span></td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit">
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="font-size: 16.0px;background-color: #ccffcc">BLVB</span></td>
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="font-size: 16.0px;background-color: #ccffcc">Condutor de alum&iacute;nio isolado PVC revestido fios apartamento</span></td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit">
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="font-size: 16.0px;background-color: #ccffcc">227IEC02RV</span><br /><span style="font-size: 16.0px;background-color: #ccffcc">227IEC06RV</span></td>
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="font-size: 16.0px;background-color: #ccffcc">Condutor de cobre isolado PVC conector flex&iacute;vel</span></td>
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none" rowspan="4"><span style="font-size: 16.0px;background-color: #ccffcc">Usado principalmente em m&eacute;dia e leve stylemoving eletr&ocirc;nica, eletrodom&eacute;sticos, energia e ilumina&ccedil;&atilde;o e os lugares onde flex&iacute;vel.</span></td>
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none" rowspan="4"><span style="background-color: #99ccff">70</span></td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit">
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="font-size: 16.0px;background-color: #ccffcc">227IECC42</span><br /><span style="font-size: 16.0px;background-color: #ccffcc">RVB</span></td>
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="font-size: 16.0px;background-color: #ccffcc">Condutor de cobre do PVC insualted plano flex&iacute;vel conector</span></td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit">
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="font-size: 16.0px;background-color: #ccffcc">RVS</span></td>
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="font-size: 16.0px;background-color: #ccffcc">Condutor de cobre isolado PVC flex&iacute;vel tor&ccedil;&atilde;o do fio conector</span></td>
</tr>
<tr style="margin: 0.0px;padding: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit">
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="font-size: 16.0px;background-color: #ccffcc">227IEC53</span><br /><span style="font-size: 16.0px;background-color: #ccffcc">RW</span></td>
<td style="margin: 0.0px;font-size: inherit;font-style: inherit;line-height: inherit;float: none"><span style="font-size: 16.0px;background-color: #ccffcc">Condutor de cobre isolado PVC PVC sheated flex&iacute;vel rodada connector (luz e tipo comum)</span></td>
</tr>
</tbody>
</table></div>
</div>
<div style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial , helvetica;line-height: 15.0px;vertical-align: baseline"><strong><span style="background-color: #99ccff;color: #800000">&nbsp;</span></strong></div>
<div style="margin: 0.0px;padding: 0.0px;border: 0.0px;font-family: arial , helvetica;line-height: 15.0px;vertical-align: baseline">
<p style="color: #333333;font-family: arial , helvetica , sans-serif;line-height: 18.0px">&nbsp;</p>
<p style="color: #333333;font-family: arial , helvetica , sans-serif;line-height: 18.0px"><strong><span style="color: #800000"><em><span style="line-height: 27.0px;font-size: 18.0px">Nossa f&aacute;brica</span></em></span></strong></p>
<p style="color: #333333;font-family: arial , helvetica , sans-serif;line-height: 18.0px"><span style="color: #000080"><em><span style="font-weight: bold"><span style="line-height: 27.0px;font-size: 18.0px"></span></span></em></span></p>
<p style="color: #333333;font-family: arial , helvetica , sans-serif;line-height: 18.0px"><span style="font-size: 18.0px;color: #003366"><strong>Embalagem</strong></span></p>
<p style="color: #333333;font-family: arial , helvetica , sans-serif;line-height: 18.0px">
<p style="color: #333333;font-family: arial , helvetica , sans-serif;line-height: 18.0px">&nbsp;</p>
<p style="color: #333333;font-family: arial , helvetica , sans-serif;line-height: 18.0px"><span style="color: #993300"><strong><span style="font-size: 18.0px">Expedi&ccedil;&atilde;o</span></strong></span></p>
<p style="color: #333333;font-family: arial , helvetica , sans-serif;line-height: 18.0px">
<p style="color: #333333;font-family: arial , helvetica , sans-serif;line-height: 18.0px">&nbsp;</p>
<p style="color: #333333;font-family: arial , helvetica , sans-serif;line-height: 18.0px">&nbsp;</p>
<p style="color: #333333;font-family: arial , helvetica , sans-serif;line-height: 18.0px"><span style="color: #800000"><strong><span style="font-size: 18.0px">Exposi&ccedil;&atilde;o</span></strong></span></p>
<p style="color: #333333;font-family: arial , helvetica , sans-serif;line-height: 18.0px"><span style="color: #800000"><strong><span style="font-size: 18.0px">Estamos a assistir cada Canton Fair cada ano, bem-vindo para nos visitar!</span></strong></span></p>
<p style="color: #333333;font-family: arial , helvetica , sans-serif;line-height: 18.0px">&nbsp;</p>
<p style="color: #333333;font-family: arial , helvetica , sans-serif;line-height: 18.0px;text-align: center">&nbsp;</p>
<div><span style="line-height: 36.0px;color: #000080;font-size: 24.0px"><em><span style="font-weight: bold">N&oacute;s estamos sempre aqui esperando por voc&ecirc;, nossos clientes!</span></em></span></div>
<div>&nbsp;</div>
<div><span style="line-height: 36.0px;color: #000080;font-size: 24.0px"><em><span style="font-weight: bold">Basta nos enviar sua pergunta, seu pedido receber&aacute; aten&ccedil;&atilde;o imediata. Obrigado.</span></em></span></div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://portuguese.baoliyy.com/pvc-insulated-wire-electric-cable-wire-1-5mm2-wire-for-home-application/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
